Intrinsically safe (Cert.No. SCS Ex96D2036) |
 |
Three independent voltage amplifiers. |
 |
Input ranges Min 0-1mV, Max 0-5V |
 |
Calibration by network digital scaling factor and offset adjustment. |
 |
Individually configurable for differential or single-ended analogue input. |
 |
Switched 5V excitation on each amplifier |
 |
Optimised for Wheatstone bridge transducers |
 |
Individually
configurable amplifier offset for true differential input. |
 |
Calibration
Shunt resistor on each amplifier (note 1)
|
 |
Calibration
check against programmable level and bandwidth
|
 |
All
voltage and calibration data is updated once per second (note
2)
|
 |
Auxiliary
analogue input and digital input/output lines
|
 |
Heartbeat
transmission every 3 seconds (note 2)
|
 |
Compatible
with LonMark approved MTL IS78 channel for the LonWorks Network
|
 |
Power
and data on a single 2 core network cable
|
 |
Up
to 3 units on a network channel (note 1)
|
 |
Network
cable distances up to 2km (note 1,3)
|
 |
Data
transmission at 78kBps
|
 |
Low
power operation - sleep mode with external or timer wakeup
|
 |
Diagnostic
capabilities built in
|